Table 16: instruction codes for protocol 3000, Kramer protocol – Kramer Electronics VP-4x8AK User Manual

Page 46

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Kramer Protocol

42

Message closing char =
Host messages - Carriage Return (ASCII 13), will be referred to by CR in this document.
Machine messages - Carriage Return (ASCII 13) + Line-Feed (ASCII 10), will be referred to by CRLF.
Spaces between parameters or command parts will be ignored.

Commands chain separator char:
When message string contains more than one command, commands will be separated by pipe ("|").

Commands entering:
If terminal software used to connect over serial \ ethernet \ USB port, that possible to directly enter all commands characters
(CR will be entered by Enter key, that key send also LF, but this char will be ignored by commands parser).
Sending commands from some controllers (like Crestron) require coding some characters in special form (like \X##).
Anyway, there is a way to enter all ASCII characters, so it is possible to send all commands also from controller.
(Similar way can use for URL \ Telnet support that maybe will be added in future).

Commands forms:
Some commands have short name syntax beside the full name to allow faster typing, response is always in long syntax.

Commands chaining:
It is possible to enter multiple commands in same string by '|' char (pipe).
In this case the message starting char and the message closing char will be entered just one time, in the string beginning
and at the end.
All the commands in string will not execute until the closing char will be entered.
Separate response will be sent for every command in the chain.

Input string max length:
64 characters.

Backward support:
Design note: transparent supporting for protocol 2000 will be implemented by switch protocol command from protocol 3000
to protocol 2000, in protocol 2000 there is already such a command to switch protocol to ASCII protocol (#56 : H38 H80 H83
H81).

Table 16: Instruction Codes for Protocol 3000

Help commands
Command

Syntax

Response

Protocol Handshaking

#CR

~OKCRLF

Device initiated messages

Command

Syntax

Start message

Kramer Electronics LTD. , Device Model

Version Software Version

Switcher actions

Audio-video channel has switched (AFV mode)

AV IN>OUT

Video channel has switched (Breakaway mode)

VID IN>OUT

Audio channel has switched (Breakaway mode)

AUD IN>OUT

Result codes (errors)

Syntax

No error. Command running succeeded

COMMAND PARAMETERS OK

Protocol Errors

Syntax Error

ERR001

Command not available for this device

ERR002

Parameter is out of range

ERR003

Unauthorized access (running command without the match login).

ERR004