7 connecting the vp-747t, Connecting the vp-747t – Kramer Electronics VP-747T User Manual

Page 13

Advertising
background image

Connecting the VP-747T

11

7 Connecting the VP-747T

To connect the VP-747T to up to four VP-747 machines, as the example in

Figure 7

illustrates, do the following

15F

1

:

1. Connect the “TO VP-747” mini XLR connector of the VP-747T (by

one-to-one connection) to the VP-747, as follows:
 MACH. # 1 to the mini XLR connector of the VP-747 which will be

recognized as machine # 1

 MACH. # 2 to the mini XLR connector of the VP-747 which will be

recognized as machine # 2

2. Connect the “TO VP-747” 3-pin terminal block ports of the VP-747T (by

wired connection) to the VP-747, as follows (see section

U

7.2

U

):

 MACH. # 3 to the mini XLR connector of the VP-747 which will be

recognized as machine # 3

 MACH. # 4 to the mini XLR connector of the VP-747 which will be

recognized as machine # 4

3. Set the “T-Bar Optimization” mode in the “Transition” menu of the

VP-747 to On.

4. Connect the 12V DC power adapter to the power socket and connect the

adapter to the mains electricity (not illustrated in

U

Figure 7

U

).

If you want to control several units simultaneously, press the MACHINE #

button until the letter A is selected in the 7-segment LED display (A=ALL).

One of the units must be connected to port #1 for units to be controlled

simultaneously.

1 Switch OFF the power on each device before connecting it to your VP-747T. After connecting your VP-747T, switch on its

power and then switch on the power on each device

Advertising