VP-771 - The VP-771 RS-232 Communication Protocol

77

77

VOLUME-PARAMETER

= output volume parameters:

[VALUE] either positive or negative digits (minus sign precedes negative values).
“+” increase current value,
“-“ decrease current value

Window
customization

WIN-CUST WINDOW, HPOS,

HW , VPOS, VH

WIN- CUST WINDOW, HPOS,

HW , VPOS, VH RESULT

Parameters Description: fast window customization
[WINDOW] “0” for main window; “1” for PiP window
[HPOS] horizontal position value
[HW] horizontal width value
[VPOS] vertical position value
[VH] vertical height value

Set dual window state

PIP PIP-MODE

PIP PIP-MODE RESULT

Get dual window state

PIP?

PIP PIP-MODE

Parameters Description:

PIP-MODE

= Dual window state:

"0" or "off" for single window.
"1" or "on" to for dual window.


Identification commands

Command

Syntax

Response

Protocol
Handshaking

#CR

~OK CRLF

Read device model

MODEL?

MODEL MACHINE_MODEL

Read device serial
number

SN?

SN SERIAL_NUMBER

Read device
firmware version

VERSION?

VERSION MAJOR .MINOR
.
BUILD .REVISION

Read device build
date

BUILD-DATE?

BUILD-DATE YYYY/MM/DD

HH:MM:SS

Read device protocol
version

PROT-VER?

PROT-VER 3000:MAJOR
.
MINOR

Set machine name

NAME MACHINE_NAME

NAME MACHINE_NAME

RESULT

Read machine name

NAME?

NAME MACHINE_NAME

Reset machine name
to factory default*

NAME-RST

NAME-RST RESULT

Network settings commands

Network settings commands require admin authorization

Command

Syntax

Response

Set IP Address NET-IP IP_ADDRESS

NTIP

NET-IP IP_ADDRESS RESULT