Using the VS-211HDxl

7

5.3

Connecting the REMOTE Terminal Block Connector

Regardless of the default input switch setting, you can force the switching
of the active input by remote control. To do this, connect the appropriate
REMOTE input terminal block connector pins to a contact closure switch

1

(see

Figure 3

).

• To force IN 1: connect REMOTE IN1 to PIN G (ground)
• To force IN 2: connect REMOTE IN2 to PIN G (ground)

Do not connect both the REMOTE IN1 and the REMOTE IN2

to PIN G simultaneously

Attach PIN IN1 to

PIN G to activate

INPUT 1

Attach PIN IN2 to

PIN G to activate

INPUT 2

Figure 3: REMOTE Terminal Block Connector
















1 Note that the connection should be permanent, since the VS-211HDxl reverts to an automatic switcher when the connection

is removed