VS-21HDCP-IR - Protocol 3000 Syntax

13

8

Protocol 3000 Syntax

With Kramer Protocol 3000 you can control the VS-21HDCP-IR from any standard

terminal software (for example, the Windows

®

HyperTerminal Application).

This RS-232/RS-485 communications protocol uses a data rate of 115,200 baud,

no parity, 8 data bits, and 1 stop bit.

8.1

Host Message Format

Start

Address (optional)

Body

Delimiter

#

Destination_id@

Message

CR

8.1.1

Simple Command

Command string with only one command without addressing:

Start

Body

Delimiter

#

Command SP

Parameter_1,Parameter_2,…

CR

8.1.2

Command String

Formal syntax with commands concatenation and addressing:

Start

Address

Body

Delimiter

#

Destination_id@

Command_1
Parameter1_1,Parameter1_2,…|
Command_2
Parameter2_1,Parameter2_2,…|
Command_3
Parameter3_1,Parameter3_2,…|…

CR

8.2

Device Message Format

Start

Address (optional)

Body

delimiter

~

Sender_id@

Message

CR LF

8.2.1

Device Long Response

Echoing command:

Start

Address (optional)

Body

Delimiter

~

Sender_id@

Command SP [Param1 ,P

aram2 …] result

CR LF

CR = Carriage return (ASCII 13 = 0x0D)

LF = Line feed (ASCII 10 = 0x0A)

SP = Space (ASCII 32 = 0x20)