Upgrading the VS-81SP Firmware
23
23
10. Click Connect.
In the Operations Flow column of the Atmel – Flip window, the Run button
is active, and the name of the chip appears as the name of the third column:
AT89C51RD2.
Verify that in the Buffer Information column, the “HEX File: VP81SP.hex”
appears.
Figure 18: Atmel – Flip Window (Connected)
11. Click Run.
As each stage of the operation completes, the check-box for that stage
changes to green
.
When the operation is complete, all four check-boxes are green and the
message Memory Verify Pass appears
1 See also the blue progress indicator on the status bar
in the status bar.
2 If an error message: “Not Finished” shows, click Run again