Vt filter recursion setting, Byosdvtrecursionset, Byosdvtrecursionget – Kramer Electronics VP-790 User Manual
Page 125: Byosdvtrecursionsave

VP-790 Protocol –
API Functions
121
2.117
125B
VT Filter Recursion Setting
2.117.1
468B
byOsdVTRecursionSet
API index: 3243
Switches the recursion filter on and off.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: Off
1: On
Switches the recursion on/off.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.117.2
469B
byOsdVTRecursionGet
API index: 3244
Retrieves the recursion filter setting.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0: Off
1: On
Recursion filter setting on/off setting
2.117.3
470B
byOsdVTRecursionSave
API index: 3245
Saves the recursion filter setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise