Figure 2: rc-54dl rear panel – Kramer Electronics RC-54DL User Manual

Page 7

Advertising
background image

RC-54DL –

Overview

5

3.2

10B

The RC-54DL KNET™ Auxiliary Control Panel Rear Side

Figure 2: RC-54DL Rear Panel

#

Feature

Function

1 RESET TO DEFAULT

Button

Disconnect the power and then connect it while pressing

the RESET TO DEFAULT button (using a small

screwdriver). The unit will power up and load its memory

with the factory default KNET ID auxiliary setting (ID=2).

This operation should be carried out by authorized Kramer

technical personnel or by a qualified system integrator, and

requires removal of the device from the wall by unscrewing the

four wall mount screws

2 PROGRAM (USB)

Connector

Connect to a computer for firmware upgrade or setting the

K-NET ID number

3 Power Supply 2-pin

Terminal Block Connector

Connect to power supply (when power is not supplied over

the K-NET)

Connect GND to GND, +12V to +12V

4 K-NET TERM Switch

Slide to the left (in the direction of the arrow) for K-NET

termination, slide to the right up to leave bus unterminated.

The last physical device on a K-NET bus must be terminated

5 K-NET1 Connector

Connect the GND pin to the Ground connection; pin B (-)

and pin A (+) are for RS-485, and the +12V pin is for

powering the unit

The ground connection is sometimes connected to the shield of

the RS-485 cable

6 K-NET2 Connector

Connect the GND pin to the Ground connection; pin B (-)

and pin A (+) are for RS-485, and the +12V pin is for

powering the unit

The ground connection is sometimes connected to the shield of

the RS-485 cable

7 Ring Tongue Terminal

Grounding Screw

Connect to grounding wire (optional), (see

Section 5

)