Your Universal Room Controller

4

Figure 2 and Table 2 define the

RC-8RK / RC-8RKL (identical) rear panel:

Figure 2: RC-8RK and the RC-8RKL Rear Panel

Table 2: RC-8RK and the RC-8RKL Rear Panel Features

#

Feature

Function

1

BRIGHTNESS

Indication

Arrow

Brightness indication to increase the brightness of the buttons

1

2

BACKLIGHT

Indication

Arrow

Backlight indication to set the backlight illumination for when the

unit is not active

3 ETHERNET Port

Connects to a PC or other controller via computer networking

4

COLOR SELECT

Indication

Arrow

Color select indication for selecting the button color

2

5

N.U

Switch

Not used

6 PROGRAM Switch

Switch to OFF for normal operation; to ON for firmware upgrade

7

RS-485 TERM.

Switch

Switch to ON for RS-485 line termination

8 FACTORY DEFAULT Button Press to return to the factory default settings, including all the

configured buttons and the network settings

3

1 See Table 5
2 See Table 4
3 Including the factory default IP number: 192.168.1.39 (an IP number is a device's numerical address as expressed in the
format specified in the Internet Protocol)