1 defining the sl-10 master room controller, Defining the sl-10 master room controller, Figure 1: sl-10 master room controller – Kramer Electronics SL-10 User Manual
Page 8
SL-10 - Overview
5
3.1
Defining the SL-10 Master Room Controller
This section defines the SL-10.
Figure 1: SL-10 Master Room Controller
#
Feature
Function
1
ETHERNET RJ-45 Connector
Connects to the PC or other serial controller through
computer networking LAN to control several AV
products over Ethernet
2
DEFAULT Recessed Pushbutton Press to reset to factory default definitions:
IP number
192.168.1.39, Mask
– 255.255.0.0
Gateway
– 0.0.0.0
First disconnect the power supply and then connect it
again while pressing the DEFAULT button. The unit
powers up and loads its memory with the factory default
definitions and erases all stored presets
3
IR Output Terminal Blocks
Connect to IR emitter cables (from 1 to 3)
4
GPI/O Terminal Blocks
Connect to various analog and digital sensors (from 1
to 2)
5
RELAYS Terminal Blocks
Connect to low-voltage relay-driven devices (from 1 to
5)
6
RS-232 Terminal Blocks
Connect to the RS-232 devices (from 1 to 2)
7
RS-485 Terminal Block
Pins B (-) and A (+) are for RS-485; Pin G may be