1 storing/recalling setups, Storing/recalling setups, Section 7.1 – Kramer Electronics SP-12HD User Manual

Page 15

Advertising
background image

Operating the SP-12HD HD-SDI Processor

13

13

display shows the current level (in digits). “0” corresponds
to normal level (“NORM”)

• Press the + button or - button once to gradually increase or

decrease the current level by one unit (the 7-segment
display shows the new level)
To increase or decrease the current level rapidly, press and
hold the + button or - button, continuously

1

• To set “NORM” of the current level rapidly, press and hold

down the + button and – button together, continuously, the
7-segment display shows “0”

To end the rapid adjustment, release the + button or –
button

• To undo the adjustment, press the appropriate button one

more time. The appropriate button no longer blinks

• To save result of adjustment, press the STORE button

twice

• To store result of adjustment in other setup #, press the

STORE button once and then select a setup # between 1
and 16 by pressing the + and – button. Then press STORE
button one more time

• If the result of the adjustment equals “NORM”, then the

appropriate button no longer illuminates, otherwise this
button continues to illuminate in main mode

7.1

Storing/Recalling Setups

You can store and recall up to 16 setups (or adjustments) in non-volatile
memory, using the STORE and RECALL buttons together with the + and –
buttons.

To store

2

• Press the STORE button and then select a setup # between 1 and

16 by pressing the + and – buttons (the current settings are saved
to that setup #)

a setup, do the following:

• Then press STORE button one more time

To recall a setup, do the following:

1 The 7-segment display starts to quickly scan the range. When it stops running, it has reached the maximum or minimum,

respectively

2 Storing a new setup over a previous setup # replaces the previous setup #