Liner and temporarily secure the Flex Liner

at the top of the chimney. Be sure to leave

2-3 inches of flex above the existing chimney

to allow for connection to the Termination Kit

(Baseplate and Adaptor). (Figure 4)

Step 5. Repeat Steps 1-4 for the second

length of Flex Liner.

Step 6. At the top of the chimney, slide the

Baseplate over the two ends of the Flex Liner

and secure it to the surrounding masonry

using masonry anchor bolts. Before installing

the Baseplate, run a bead of non-hardening

sealant between the Baseplate and the

masonry to prevent moisture from entering the

chimney. (Figure 5)

Note: Verify that there is sufficient room to

mount the Baseplate on to the masonry. You

must have a level surface in order to install the

Baseplate properly.

Step 7. Attach the Flex Liner ends at the top

of the chimney to the Co-Linear to Co-Axial

Adaptor. Use four sheet metal screws to

connect each Flex Liner run to the Adaptor.

(Figure 6) Mount the Adaptor to the Baseplate

using sheet metal screws as shown. (Figure 7)

Step 8. Twist lock the Vertical Termination

Cap (Standard or High Wind) to the Adaptor.

(Figure 8) Note: If you are planning to extend

the height of the chimney using DirectVent Pro

Pipe, please refer to the Direct Vent Installation

Instructions for information concerning the

proper procedure and restrictions of Direct

Vent Pipe. Also, consult the appliance

manufacturer for any height restrictions on the

chimney.

Step 9. Depending upon the type of

connection that your appliance has, it will

require either the Co-Linear Flex Connectors

or a Co-Axial to Co-Linear Appliance

Connector in order to attach the Flex Liners to

the appliance. For the Co-Linear connection,

attach the Co-Linear Flex Connectors to the

two outlets on the back of the appliance. See

the appliance manufacturer’s instructions for

details. Connect the two Flex Liner runs to

the Connectors using four sheet metal screws

each. For the Co-Axial connection, twist lock

the Co-Axial to Co-Linear Appliance Connector

to the adaptor on the appliance. Attach the

Figure 5