an optional pipe collar is available for decorative

purposes.

6. Connectors. Only DuraVent connectors

should be used between the appliances and the

venting system. Some appliances require Type

B-Vent as a complete dedicated system from the

flue collar of the appliance to the termination of

the vent to the outside atmosphere. DuraVent’s

Duraconnect, a uL listed flexible connector, can

be used if single wall connectors are allowed. If

a B-vent connector is required, uL listed double

wall flexible Duraconnect II, can be used.

7. Elbows. When Elbows are required, strap the

pipe Sections and/or Elbows in place using Wall

Straps. Important: the offset must be supported

with Wall Straps to prevent the weight from

stressing the elbows, as shown in Figure 10.

8. Tees and Wyes. Tees and Wyes are

used to combine connectors from 2 or more

appliances into a common vent as shown in

Figures 2 and 3. a Tee should be used in

a through-the-wall application, (Figure 11),

as they have a removable Tee cap (available

as a separate item) attached to the bottom.

This Tee cap may be removed in order to

inspect the system, or to clean out debris or

collected condensate from the common vent.

Wall Straps should be used to support the

vertical pipe as needed to provide a secure

installation. Wall Straps every four feet are

required.

9. Enclosures. any portion of the vent which

passes through an occupied area must be

enclosed, to prevent accidental damage to

the system, as well as burns. Figure 1 shows

a system which passes through an occupied

second floor. DuraVent does not recommend

installation of B-Vent pipe on the outside wall

of a building, particularly in cold climates. If

it is necessary to do this, enclose the outside

portion of the system in a chase, as shown

in Figure 11. consult the Local authority

Figure 9

STEp 1

STEp 2

STEp 3

Figure 10

1 IncH

MInIMuM

cLEaRancE TO

cOMBuSTIBLES

aT aLL pOInTS

WaLL STRap

WaLL STRapS

ELBOW GORES

cEILInG SuppORT

EXISTInG

STRucTuRE