Commissioning, operation – WIKA A-10 User Manual

Page 17

Advertising
background image

17

WIKA operating instructions pressure transmitter model A-10

11218720.10 01/2012 GB/D/F/E

GB

6. Commissioning, operation

6. Commissioning, operation

Required tool: Open-ended spanner (spanner width 27), screwdriver

CAUTION!

Prior to commissioning, the pressure transmitter must be subjected to a visual inspection.

■

Leaking fluid is indicative of damage.

■

Only use the pressure transmitter if it is in perfect condition with respect to safety.

Making the mechanical connection

■

For model A-10 with parallel thread, the sealing ring is included in the delivery.

■

During mounting, make sure that the sealing faces at the pressure transmitter

and the measuring point are clean and undamaged.

■

Only ever screw in, or unscrew, the instrument via the spanner-flats and to

the prescribed torque using an appropriate tool. The correct torque depends

on the dimensions of the pressure connection and the gasket used (form/

material). When screwing in or unscrewing the pressure transmitter, do not

use the housing for purchase.

■

When screwing in, do not cross the threads.

■

For information on tapped holes and welding sockets, see Technical Information IN 00.14 at

www.wika.com.

max. 50 Nm

Advertising