WIKA DPT-10 User Manual
Page 10

Density measurement
=
∆p
h g
+
–
h
Fig. 5: Density measurement with DPT10, h = defined mounting distance, Δp =
differential pressure, ρ = density of the medium, g = acceleration of gravity
1
DPT10
Interface measurement
1
+
–
h
2
3
Fig. 6: Interface measurement with DPT10
1
DPT10
2
Liquid with highest density
3
Liquid with lowest density
A metallic measuring cell is used as sensor element. The process
pressures are transmitted via separating diaphragms and filling oils to
the resistance measuring bridge (semi-conductor technology). The
differential-pressure dependent change of the bridge voltage is
measured, further processed and converted into a corresponding
output signal.
Functional principle
10
Differential pressure transmitter DPT10 - metal measuring diaphragm • Foundation Fieldbus
3 Product description
37246
-EN
-100120