Gb 8. spare part kit – WIKA HP-2 User Manual

Page 16

Advertising
background image

16

WIKA operating instructions pressure transmitter, model HP-2

11379180.03 09/2013 GB/D/F/E

GB

8. Spare part kit

8.3 Mounting

Secure the clamping jaw in the vice as shown, so that

this cannot come loose.

Slide the pressure transmitter between the clamping

jaw, using the groove milled into the process connec-

tion.

Loosen the process connection using the torque

spanner.

Dry the baffle plate incl. the

O-ring using compressed air.

For access, there is a bore

on the process connection.

Baffle plate

DIPS

EPC

Advertising