WIKA A2G-15 User Manual

Page 7

Advertising
background image

WIKA operating instructions air2guide models A2G-10, A2G-15

7

GB

40197310.04 04/2012 GB/D/F/E/I

3. Specifications / 4. Design and function

Process connection

In accordance with the general technical regulations for pressure

gauges (e.g. EN 837-2 "Selection and installation recommendations for

pressure gauges"), plastic, G 1/8 female threads

Permissible temperature

Ambient:

-30 … +80 °C

Medium:

-16 … +50 °C

Temperature effect

When the temperature of the measuring system deviates from the

reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value

Ingress protection

IP 54 per EN 60529 / lEC 529, optional IP 65

EMC directive

Per EN 61000-6-4 and EN 61000-6-2 (cable length max 30 m)

For further specifications see WIKA data sheet PM 07.40, PV 17.40 and

the order documentation.

4. Design and function

Description

■

Nominal size 110 mm

■

The instruments measure the pressure by means of diaphragms

(silicone)

■

The measuring characteristics are in accordance with the EN 837-3

standard and ventilation and air conditioning (VAC) regulations

Scope of delivery
Cross-check the scope of delivery with the delivery note.

Advertising
This manual is related to the following products: