WIKA operating instructions pressure gauge model 4 per ATEX

Temperature class of the ambient

explosive atmosphere

(ignition temperature)

Maximum permissible medium

temperature (in the measuring

system)

T 6 (85 °C < T ≤ 100 °C)

+70 °C

T 5 (100 °C < T ≤ 135 °C)

+85 °C

T 4 (135 °C < T ≤ 200 °C)

+100 °C or +120 °C

1)

T 3 (200 °C < T ≤ 300 °C)

+100 °C or +185 °C

1)

T 2 (300 °C < T ≤ 450 °C)

+100 °C or +200 °C

1)

T 1 (T > 450 °C)

+100 °C or +200 °C

1)

2. Safety

2.3 Safety instructions for pressure gauges per ATEX

WARNING!

Non-observance of these instructions and their contents may

result in the loss of explosion protection.

WARNING!

It is imperative that the application conditions and safety require-

ments of the EC-type examination certificate are followed.

Pressure gauges must be earthed via the process connection!

Specifications
Operating temperatures
Ambient: -20 … +60 °C

with option silicone oil filling: -40 ... +60 °C

Medium: The permissible medium temperature does not only depend on the

instrument design, but also on the ignition temperature of the surround-

ing gases, vapours or dust. Both aspects have to be taken into account.

For permissible maximum medium temperatures see table 1.

Attention! With gaseous substances, the temperature may increase as a result

of compression warming. In these cases it may be necessary to throttle the rate

of change

of pressure or reduce the permissible medium temperature.

Table 1: Permissible medium temperature

1) The higher values apply only to special versions with higher permissible medium temperatures.

Advertising