Specifications – WIKA LSD-30 User Manual

Page 12

Advertising
background image

F

M

250

189

370

309

410

349

520

459

730

669

F

M

250

205

370

325

410

365

520

475

730

684

Parallel thread

Tapered thread

12

WIKA operating instructions level switch model LSD-30

GB

11613033.01 01/2012 GB/D/F/E

Insertion lengths in mm

Legend:

F = probe length

M = max. measuring range

3.6 Accuracy (electronics)
Switching and indication accuracy at room temperature

1% of span (display ±1 digit)
Analogue signal

≤ ± 0.5 % of span

Legend:

F = probe length

M = max. measuring range