Winland Electronics WB200 User Manual

Wb-200

Advertising
background image

Electronic Water Detection Device

© 2012 Winland Electronics, Inc.

D-011-0116 Rev C (08/2012)

O

NE

Y

EAR

L

IMITED

W

ARRANTY

Winland Electronics, Inc. (“Winland”) warrants to the end user/purchaser that each product of its manufacture shall be free from defects in material and
factory workmanship for a period of one year from the date of purchase, when properly installed and operated under normal conditions according to
Winland’s instruction. Winland’s obligation under this warranty is limited to correcting, without charge, at its factory any part or parts thereof which shall
be returned to the factory, by the original purchaser, transportation charges prepaid, within one year of the date of purchase and which upon examination,
shall disclose to Winland’s satisfaction to have been originally defective. Correction of such defects by repair to, or supplying replacements for, defective parts
shall constitute fulfillment of all Winland’s obligations to purchaser under this limited warranty. Repair service performed by Winland after one year from
date of purchase will be for a reasonable service charge. This limited warranty shall not apply to any of Winland’s products which have been subject to misuse,
negligence or accident or which have been repaired or altered outside of Winland’s factory. The warranty is void if the Product’s housing or cover is removed.
Winland shall not be liable for loss, damage or expense resulting, directly or indirectly, from the use of its products or any other cause. This warranty shall
be null and void in its entirety if: (i) the product is altered or modified in any way that is not consistent with the manufacturer’s instructions, or (ii) the
product is used with or connected to a device: (a) that such product is not intended to be used with or connected to, (b) is not otherwise consistent with the
manufacturer’s instructions, or (c) is not otherwise approved by the manufacturer. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES, NON-INFRINGEMENT AND TITLE, AND ANY
WARRANTIES ARISING FROM COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE. ALL OTHER REPRESENTATIONS MADE TO THE END USER/PURCHASER BY
ANY OTHER PARTY ARE ALSO EXCLUDED. WINLAND SHALL NOT BE LIABLE TO ANY PERSON FOR INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OF ANY DESCRIPTION, WHETHER ARISING OUT OF WARRANTY OR OTHER CONTRACT, NEGLIGENCE OR OTHER TORT, OR OTHERWISE. Under no circumstances
shall Winland’s liability under this limited warranty exceed the purchase price paid by the end user/purchaser for the product. No person, agent or dealer is
authorized to give warranties on behalf of Winland nor to assume for Winland any other liability in connection with any of its products.

S

PECIFICATIONS

Power Requirement

8-28 VDC @ 35mA

8-28 VAC @ 100mA

Sensitivity

Will not alarm due to high humidity or condensation.

Operating Temp

32˚ to 130˚F (0˚ to 54˚C); non-condensing environment (indoor use only)

Output

1 Form C Relay (N.O./N.C.)

1 Amp @ 30 VDC, resistive

1 Amp @ 24 VAC, resistive

Probe Options

Includes 1 Standard Unsupervised Surface Probe (W-S-U)

Accepts up to 6 Unsupervised Surface Probes (W-S-U) wired in parallel or

Accepts up to 6 Unsupervised Under Carpet Probes (W-UC-U) wired in parallel.

Max Cable Length

1-2 probes; max recommended distance of 200’ (61 m)

3-6 probes; max recommended distance of 100’ (30.5 m)

Probe Cable

Probes include 15” (4.6 m) cable. Extend using 22-18 AWG twisted pair.

Console Weight

2.4 oz (0.07 kg)

Console Dimensions

4.1 x 2.36 x 1.18” (10 x 6 x 3 cm) with flanges

Probe Dimensions

Surface: 2 x 3 x 0.88” (5.1 x 7.6 x 2.2 cm)

Under Carpet: 2 x 3 x 0.18” (5.1 x 7.6 x 0.5 cm)

Mounting

Flanges

Case Material

ABS

Warranty

1 Year Limited

C

ONTENTS

This package contains:

• 1 WB-200
• 1 Surface Probe - Unsupervised (W-S-U)
• 1 Installation/Operating Instructions Guide

WB-200

A

DDITIONAL

P

ROBES

Multiple probes must be connected in parallel to the two
“sensor” terminals. The WB-200 accepts up to 6 probes
wired per console.

W-S-U

Water Probe - Surface

Unsupervised

W-UC-U

Water Probe - Under Carpet

Unsupervised

Tech Support 8:00am - 5:00pm Central Time

(800) 635-4269 • +1-507-625-7231 P

www.winland.com

WEEE Product Recovery/Recycling for EU Customers

In an effort to improve waste management in the European Union, the European Union has enacted directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE Directive). According to the WEEE Directive, Winland Electronics must take back waste electrical or electronic equipment covered under the
WEEE Directive, at its cost, for all product it puts on the market after July 1, 2006. The Return Process: Contact Winland via our web site at www.winland.com.

Radio Frequency Interference Requirements: This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

CE Marking and European Union Compliance: Products intended for sale within the European Union are marked with the CE Mark,
which indicates compliance to applicable Directives and European Norms (EN). Amendments to these Directives or ENs are included:
Electromagnetic Compatibility Directive 2004/108/EC; Low Voltage Directive 2006/95/EC; RoHS Directive 2002/95/EC; WEEE Directive
2002/96/EC.

Statement of Compliance: Winland Electronics, Inc. hereby declares that this device is in compliance with all the applicable Directives
2004/108/EC, 2006/95/EC, 2002/95/EC, 2002/96/EC.

Symbols on the Product or Manual Labeling

For product disposal, ensure the following:
• Do not dispose of this product as unsorted municipal waste.
• Collect this product separately.
• Use collection and return systems available to you.

WEEE Waste Electrical and Electronic Equipment
RoHS Restriction of Hazardous Substances

Advertising