Error commands, Technical parameters – RADWAG WPT/P 60 Postal Scales for Packages User Manual
Page 46

- 46 -
19. ERROR COMMANDS
Err2
- Value beyond the zero range
Err3
- Value beyond the tare range
Err4
- Calibration mass or start mass beyond the acceptable
range (
±1% for weight, ±10 for start mass)
Err8
- Exceeded the time for tarring, zeroing, start mass
adjustment or span adjustment
NULL
- Zero value from the AD converter
FULL2
- Measurement
range overflow
LH
- Start mass error, the mass on the weighing platform is
beyond the acceptable range (-5% to +15% of start mass)
Notice:
1. Errors: Err2, Err3, Err4, Err8, null, that appear on the display
are also signalled by a short beep sound (about 1 sec.);
2. Error FULL2 that appears on the display is also signalled by
a continuous sound until the cause of error disappears.
20. TECHNICAL PARAMETERS
Scale type:
WPT/P 2
WPT/P 60
Max capacity
2kg
60kg
Min capacity
5g
100g
Reading accuracy
1g
20g
Verification scale interval
1g
20g
Range of tare
-2kg
-60kg
Pan size
230 x 160mm
400 x 500mm
Power supply
230V 50Hz/11V AC and 6xAA (NiMH)
Temperature of work
0
°C to +40°C
Average operation when supplied
from batteries
35 hours (average time)
Display
LCD with backlight
Net / Gross weight
3,5 / 4,8kg
15,5 / 17,8kg
Package dimensions
400 x 380 x 110mm
720 x 580 x 220mm