Alarm code list, Confidential – KMW Communications AMS Lite User Manual

Page 10

Advertising
background image

Sheet 10 of 30

Sheet 10 of 30 8/17/2008

©

CONFIDENTIAL

- AISG v2.0 7.1

0x01: RET

0x02: TMA

Maker

ALD Manufacturer

2Byte

Serial

ALD Serial NO.

17Byte

Model

ALD Model

15Byte

ROM Ver

ALD S/W Version

H/W Ver

ALD H/W Version

Tilting Deg.

Antenna Tilt Degree

Steering Deg.

Antenna Azimuth Degree

TMA Gain

Gain

13dB Fixed

Link Alarm

Normal: Green, Alarm: Red

Communication error.

(When disconnected or

the information between ALD and

TICU are different)

Connect

Connect: Green, Not Connected: Red

) Alarm Code List

Displays return codes specified in AISG 2.0.

- 3GPP TS 25.463 V6.4.0 Annex A: Return codes for secondary devices

- AISG Standard No. AISG v2.0 Annex B: Return Codes for AISG ALDs

ITEM

Description

Remark

Motor Jam

Motor cannot move

Actuator Jam

Actuator jam has been detected. No movement of the actuator,

but movement of the motor was detected

Busy

The device is busy and cannot respond until an ongoing activity

is completed

CheckSum Error

Checksum incorrect for otherwise valid data.

Not Calibrated

The device has not completed a calibration operation, or

calibration has been lost

Not Configured

Actuator configuration data is missing

Hardware Error

Any hardware error, which cannot be classified. May not be

reported as an alarm until the fault is likely to be persistent

Out of Range

A parameter given by an operator (e.g. tilt value or memory

offset) is out of range