Voltage check pont -19, Chapter 2 voltage check pont, Voltage check pont: fv1 – MSI Z68A-GD55 (G3) User Manual

Page 35

Advertising
background image

2-19

MS-7681

Chapter 2

Voltage Check Pont

Voltage Check Pont: FV1

Ths voltage check pont set s used to measure the current CPU/ CPU_VTT/ CPU_

GFX/ DDR/ PCH voltage.

CPU voltage: measure the current CPU voltage

wth CPU pont and GND pont by usng a mul-

tmeter.

CPU_VTT voltage: measure the current CPU_

VTT voltage wth CPU_VTT pont and GND

pont by usng a multmeter.

DDR voltage: measure the current DDR voltage

wth DDR pont and GND pont by usng a mul-

tmeter.

PCH voltage: measure the current PCH voltage

wth PCH pont and GND pont by usng a mul-

tmeter.

DDR

GND

GND

1

7

PCH

CPU_GFX

CPU_VTT

CPU

GND

1

7

CPU

GND

1

7

CPU_VTT

GND

1

7

CPU_GFX

GND

1

7

DDR

GND

1

7

PCH

CPU_GFX voltage: measure the current CPU

Integrated Graphc voltage wth CPU_GFX pont

and GND pont by usng a multmeter.

Advertising