Degraded raid array, Append x b, Append x b degraded raid array – MSI H67MA-E45 (B3) User Manual

Page 76

Advertising
background image

B-12

Intel RAID

MS-7678

Append

x B

Intel RAID

MS-7678

Append

x B

Degraded RAID Array

A RAID 1, RAID 5 or RAID 10 volume s reported as degraded when one of ts hard drve

members fals or s temporarly dsconnected, and data mrrorng s lost. As a result, the

system can only utlze the remanng functonal hard drve member. To re-establsh

data mrrorng and restore data redundancy, refer to the procedure below that corre-

sponds to the current stuaton.

Mssng Hard Drve Member

Make sure the system s powered off.
Reconnect the hard drve.
Reboot the system to Wndows; the rebuld wll occur automatcally.

Faled Hard Drve Member

Make sure the system s powered off.
Replace the faled hard drve wth a new one that s of equal or greater capacty.
Reboot the system to Intel RAID Opton ROM by press <Ctrl> and <I> keys smul-

taneously durng the Power-On Self Test (POST).

1.
2.
3.

1.
2.
3.

Select the port of the destnaton dsk for rebuldng, and then press ENTER.

4.

Advertising
This manual is related to the following products: