Silent Call WCV08-SS User Manual

Page 4

Advertising
background image




Battery Back-up Instructions

Your Silent Touch Watch Docking Station comes with the battery back-up pre-installed at the factory. In the event that you need
to replace the battery back-up pack, you will need to send it to Silent Call Communications for replacement. Attempting to change
the battery pack yourself will void your warranty and possibly damage your docking station. Please note that batteries are not
warranted and you will be charged the current rate for the battery at that time.

The Ni-Cad battery is intended to keep the Silent Touch Watch Receiver while in the docking station, operational during a short
term power outage for several hours without the vibrator operating. If the vibrator is operating, the battery back-up will operate
the system for approximately 10 minutes. The battery back-up is automatically being charged when the Silent Touch Docking
Stations power supply is plugged into a standard electrical wall outlet.

The Battery Icon will display itself on the LCD screen of the Silent Touch Watch at all times to let you know the level of the battery
charge. The Battery Icon has 3 segments of cells. When the battery is fully charged all 3 segments will be displayed. As the
battery charge is depleted, the cells will drop down to 2 cells and then 1 cell and you will know that the Silent Touch Watch will
need to be charged soon.

Supervision Mode for Smoke and Fire Transmitters:

The “Silent Touch” watch receiver is capable of monitoring up to three Silent Call Smoke Detectors and/or Fire
transmitters for low battery, out of range, interference from outside sources, and missing or failure of the transmitter to
communicate with the receiver. The MODE is referred to as the SUPERVISOR MODE.

All 418 MHz Signature Series Silent Call Fire and Smoke Detector transmitters send out a special alarm signal at two
minute intervals. The receiver will continue to operate in its normal mode provided the unit is receiving the supervisory
alarm signals from the Smoke or Fire transmitter. The receiver will alert the user if a Smoke Detector or Fire
transmitter signal has not been received within a period of 10 minutes. When this happens, the watch LCD will flash
the FIRE ICON and the CHK ICON for 10 seconds every 30 seconds. Also, the F1, F2 or F3 Icon that corresponds to
the smoke detector or fire transmitter having a problem, will be displayed in the watch.

The “Silent Touch” watch automatically enters the supervisor mode once it has been programmed for a smoke
detector(s) or fire alarm transmitter(s). Each Smoke Detector or Fire alarm transmitter must be assigned an address
different from all other transmitters. For example, if two smoke detectors and one fire alarm transmitter are being used,
they may be assigned Address # 1,( 1 Off, and 2, 3,4, 5 ON), Address # 2 (1 ON, 2 OFF, 3,4,5 ON) , and Address # 3
(1,2 ON, 3 OFF, 4, 5 ON). When using different addresses, as mentioned above, you can place the smoke detectors or
fire transmitters is different areas of your home or workplace and know exactly which unit is or is not operating as it
should.

Equipment Test:
Once you have completely setup your Silent Call equipment and programmed the transmitters to the receiver, be sure to
run a complete test of your products by following the instructions enclosed with each transmitter.

Technical Support

For technical support on this or any other Silent Call product, please feel free to contact us. You can reach us by phone at 800-
572-5227 (voice or TTY) or by Email at

[email protected]


Limited Warranty
Your “Silent Touch” Watch receiver and Charger/Docking Station are warranted to be free of defects in material and workmanship
for five years from the date of initial purchase (not including the battery). During that time, the unit will be repaired or replaced
free of charge when shipped prepaid to Silent Call Communications. Please include your telephone number or other ways we can
contact you. This warranty is void if the defect is caused by customer abuse or neglect.

Technical Data:
Frequency

418 Mhz

Advertising
This manual is related to the following products: