Troubleshooting – American Dryer Corp. AD-27 User Manual

Page 39

Advertising
background image

35

SECTION VIII

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and

THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED
FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING,
ADJUSTING, INSTALLATION, or TESTING OF ANY EQUIPMENT per
OSHA
(Occupational Safety and Health Administration) STANDARDS.

The information provided will help isolate the most probable component(s) associated with the difficulty described.
The experienced technician realizes, however, that a loose connection or broken/shorted wire may be at fault
where electrical components are concerned ... and not necessarily the suspected component itself.

Electrical parts should always be checked for failure before being returned to the factory.

The information provided should not be misconstrued as a handbook for use by an untrained person making
repairs.

IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the fuse

being replaced.

WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BY A

QUALIFIED PROFESSIONAL or SERVICE AGENCY.

WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS

DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.

MICROPROCESSOR CONTROLLER (COMPUTER) MODELS

A.

No display (microprocessor controller [computer] models ONLY)...

1. Service panel fuse blown or tripped breaker.

2. Blown control circuit L1 or L2 1/2-amp (Slo Blo) fuse.

3. Failed microprocessor controller (computer).

B.

Drive motor is not operating (does not start)...

1. Microprocessor controller (computer) motor indicator dot and relay output light emitting diode (L.E.D.)

indicator are on ...

a. Failed drive motor contactor (relay).

b. Failed drive motor.