8

CBD Model Machines

B. Control

Board

Auger Movement

The Auger Movement button controls the operation
of the augers. The augers must be rotating to start
the refrigeration cycle.

Cold Selection

The Cold Selection button changes the
refrigeration style depending on the product type
selected. Press the <<>> button to toggle between
“motor on” mode, slush and cold drink. The ice
crystal LED is lit during slush mode. There are
three density levels for slush mode shown by the
slush density indicator. The water droplet LED is
lit during cold drink mode. No LEDs are lit during
“motor on” mode.

Refrigeration Indicator

The Refrigeration Indicator is lit during a
refrigeration cycle.

Slush Density Indicator

The Slush Density Indicator shows the density
setting of the slush mode. The “1” setting is the
lowest density (lowest consistency) and the “3”
setting is the highest density.

C.

24 Hour Timer

If the machine has a timer, it can be programmed
for defrost mode at specifi c intervals. The timer
is located behind the right panel. To program the
timer, refer to Section 2.4.

D. Spigot

Lock

The Spigot Lock is a lever located behind the
spigot handle that locks the spigot handle in the
open or closed position. When the spigot is in
the desired position, push the lever clockwise to
lock it in place. Unlock the spigot by moving the
lever counterclockwise.

3.3 ASSEMBLY OF MACHINE

All parts should be cleaned, sanitized and allowed to air
dry before assembling.

To Assemble the machine parts, refer to the following steps:

A.

Press the gear into bottom of the vertical auger
and install the auger. Secure it to the machine
with the fastening nut.

Cold

Selection

Auger

Movement

Figure 3-2 Control Board

CAUTION

Pinch Point

When the spigot handle is locked in the open po-
sition it can pinch and cause injury. Do not place
your hand between the spigot handle and spigot
assembly when it is locked in the open position.

Figure 3-3 Installing Augers

Vertical

Auger

Horizontal

Auger

Gear

Gear

Fastening

Nut