Section 8 troubleshooting and repair, 1 before considering trouble – Anritsu MP1763C User Manual

Page 73

Advertising
background image

8-1

SECTION 8

TROUBLESHOOTING AND REPAIR

8.1 Before Considering Trouble

If the instrument is not operating properly for some reason, check it as follows:

•

Power is not turned on

Is the power cord loose ?

→

Plug in firmly.

↓

Is the fuse blown ?

→

Replace the fuse.

•

Synchronization is not established.

Are the transmit and receive interfaces the same ?

→

Check the set values and set them to the correct values.

(Termination conditions, output level, offset, etc.)

↓

Is the connection cable normal ?

→

Change the cable.

↓

Initialize the instrument. (Transmitter and receiver)

Set the receiver the same as the transmitter.

•

Error added

Is the cable loose ?

→

Retighten the connector.

↓

Is Error addition OFF ?

→

Set Error addition to OFF.

↓

Are the phase margin and bias margin sufficient?

→

Adjust so that the phase and offset are suitably cut.

•

The output waveform is distorted.

Is the cable loose ?

→

Retighten the connector.

↓

Is the CLOCK1 outputs terminated ?

→

use the attached cable to connect the outputs to the

↓

DUMMY terminal.

Are cables and connectors that have good high

→

Use cables and connectors that have good high fre-

frequency characteristics being used ?

quency characteristics.

Advertising