Optional exhaust installations

This dryer can be converted to exhaust out the right side, left
side, or through the bottom.

Contact your local dealer to have the

dryer converted.

WARNING

Fire Hazard

Cover unused exhaust holes with one of the
following kits:

279818 (white)

W10186596 (midnight grey)

Contact your local dealer.

Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.

A

B

C

A. Standard rear offset exhaust installation
B. Left or right side exhaust installation

C. Bottom exhaust installation (not an option

with pedestal installations)

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.

A

B

A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation

NOTE: The following kits for close clearance alternate
installations are available for purchase. To order, please see

the “Assistance or Service” section.

Over-the-Top Installation:

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent
mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (457.2 mm)
mismatch

Part Number 4396011 - 18" (457.2 mm) to 29" (736.6 mm)
mismatch

Part Number 4396014 - 29" (736.6 mm) to 50" (1270 mm)
mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most
direct path outdoors.

Plan the installation to use the fewest number of elbows and
turns.

When using elbows or making turns, allow as much room

as possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.

Determine vent length and elbows needed for best
drying performance

Use the following Vent system chart to determine type of vent
material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and
increased energy usage.

The Vent system chart provides venting requirements that will
help to achieve the best drying performance.

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add one
90º turn to the chart.

Number of

90º turns

or elbows

Type of vent

Box or

Louvered

hoods

Angled

hoods

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)