References – Allied Telesis Rapier Switch User Manual

Page 3

Advertising
background image

Application Note

3

Allied Telesyn Guide to Ingress Rate Limiting on the Rapier-i
C613-43002-00 REV A
June 23, 2003

Add ports 1 and 2 to the VLAN, using the command:

add vlan=2 port=1,2

Set the Egress Limit on port 2, using the command:

set switch port=2 egresslimit=2000

Link port 2 to port 3, using a cross-over cable.

This set up, shown in Figure 2, has the effect of setting an Ingress Rate Limit of
2Mbps on Port 1 with the benefit of buffering. The result is that the end-to-end
throughput of the traffic from host 1 to host 2 will be very close to the
configured limit of 2Mbps.

Figure 2: Rate limiting on the Rapier-i

References

E. Altman, J. Bolot, P. Nain, D. Elouadghiri, M. Erram-dani, P. Brown, and D.
Collange, “Performance Modeling of TCP/IP in a Wide-Area Network”, 34th
IEEE Conference on Decision and Control, Dec. 1995.

K. Fall and S. Floyd, “Simulation-based Comparisons of Tahoe, Reno, and
SACK TCP” Computer Communication Review, Jul. 1996.

A. Kumar, “Comparative Performance Analysis of Versions of TCP in a Local
network with a Lossy Link”, IEEE/ACM Transactions on Networking, Aug.
1998.