Cooling fan faults, Thermal cooling, Cooling – Lenovo Secure Managed Client User Manual

Page 37: Faults, Thermal

Advertising
background image

Cooling

fan

faults

Table

14.

Cooling

fan

faults

Symptom

Cause

Action

1.

Front

panel

fault

LED

amber

2.

Audible

alarm

sounding

3.

Fan

LED

is

illuminated

1.

Any

power

fault

2.

A

fan

failure

1.

Check

to

ensure

DC

power

to

cooling

fans

is

correct

and

that

the

LED

is

not

illuminated

2.

Disconnect

the

PSU

from

main

power

and

remove

the

faulty

fan

from

the

system.

Re-install.

If

problem

persists,

replace

PSU.

3.

Reduce

the

ambient

temperature

Thermal

cooling

The

Secure

Managed

Client

(SMC)

-

Storage

Array

uses

extensive

thermal

monitoring

to

ensure

component

temperatures

are

kept

low

and

acoustic

noise

is

minimized.

Airflow

is

from

front

to

rear

of

the

enclosure.

Table

15.

Thermal

cooling

Symptom

Cause

Action

If

the

ambient

air

is

cool

(below

25°C

or

77°F)

and

the

fans

are

observed

to

increase

in

speed

then

some

restriction

on

airflow

may

be

causing

an

additional

internal

temperature

rise.

Note:

This

is

not

a

fault

condition.

The

first

stage

in

the

thermal

control

process

is

for

the

fans

to

automatically

increase

in

speed

when

a

thermal

threshold

is

reached.

This

may

be

caused

by

higher

ambient

temperatures

in

the

local

environment

and

may

be

perfectly

normal.

Note:

This

threshold

changes

according

to

the

number

of

drives

and

power

supplies

installed.

1.

Check

the

installation

for

any

airflow

restrictions

at

either

the

front

or

rear

of

the

enclosure.

A

minimum

gap

of

2.5

cm

(1

inch)

at

the

front

and

5

cm

(2

inches)

at

the

rear

is

recommended.

2.

Check

for

restrictions

due

to

dust

build

up;

clean

as

appropriate.

3.

Check

for

excessive

re-circulation

of

heated

air

from

rear

to

front.

Use

in

a

fully

enclosed

rack

installation

is

not

recommended.

4.

Check

that

all

blank

modules

are

in

place.

5.

Reduce

the

ambient

temperature.

Chapter

5.

Troubleshooting

and

problem

solving

29