Replacing the sas controller, Replacing, Controller – Lenovo ThinkServer RD120 User Manual

Page 41

Advertising
background image

1

Access

holes

3

Release

tabs

2

Guide

4

Guide

7.

Connect

any

required

cables

to

the

adapter.

Attention:

v

When

you

route

cables,

do

not

block

any

connectors

or

the

ventilated

space

around

any

of

the

fans.

v

Make

sure

that

cables

are

not

routed

on

top

of

components

under

the

PCI

riser-card

assembly.

v

Make

sure

that

cables

are

not

pinched

by

the

server

components.

8.

Perform

any

configuration

tasks

that

are

required

for

the

adapter.

If

you

have

other

optional

devices

to

install,

do

so

now.

Otherwise,

go

to

“Completing

the

installation”

on

page

29.

Replacing

the

SAS

controller

A

SAS

controller

can

be

installed

only

in

a

dedicated

slot

on

the

system

board.

The

server

comes

with

a

ServeRAID-8k-l

SAS

Controller

installed.

Note:

The

ServeRAID-8k-l

SAS

Controller

does

not

have

a

battery.

To

replace

the

ServeRAID-8k-l

SAS

Controller

with

a

ServeRAID-8k

SAS

Controller,

complete

the

following

steps:

1.

Read

the

safety

information

that

begins

on

page

v

and

the

“Installation

guidelines”

on

page

7.

2.

Turn

off

the

server

and

peripheral

devices

and

disconnect

all

power

cords

and

external

cables

(see

“Turning

off

the

server”

on

page

37).

Chapter

2.

Installing

optional

devices

27