Advertising
Drum unit, Ozone filter, Toner filter replacement instructions
2
3.
Loosen the shoulder screw [1], and
pull out the drum unit [2].
4.
Hold the fixed lever [1] for the drum
unit at two positions, and remove the
drum unit [2] while loosening the
fixed lever.
1.2
Reinstall procedure
1.
Remove the new drum unit from the
black protective bag.
2.
Remove caps [1] at the front and the
back of the drum unit.
A2WUF2C058DA
[2]
[1]
A2WUF2C059DA
[2]
[1]
[1]
A0P0F2C525DA