Konica Minolta bizhub C250 User Manual

Page 28

Advertising
background image

Administrator Operations

2

C250

2-9

Ad

minist

ra

to

r Op

er

at

ions

Chapter 2

Setting the Enhanced Security mode to [ON] changes the setting values of
the following functions.

Image Controller Setting

Calls for setting made by the Service Engineer. For details, ask
your Service Representative.

Management Function
Choice

CE Password

CE Authentication

CS Remote Care

HDD

Settings to be Made in
Advance

Description

Function Name

Factory Setting

When Enhanced Security mode is set to [ON]

Password Rules

OFF

ON (not to be changed)

Prohibit Function When
Auth. Error

Mode 1

Mode 2 (not to be changed)
Three times is set.
* In association with Secure Document Access
Method, the method is changed from authenti-
cation using Secure Document ID and pass-
word (Mode 1) to that using the password with
the secure document first narrowed down by
Secure Document ID (Mode 2).

Public User Access

Restrict

Restrict (not to be changed)

User Name List

OFF

OFF (not to be changed)

Print Without Authenti-
cation

Restrict

Restrict (not to be changed)

User Box Admin. Setting

Restrict

Restrict (not to be changed)

SSL

OFF

ON (not to be changed)

FTP Server

ON

OFF (not to be changed)

SNMPv1/v2c

Read/Write en-
abled

Only Read is enabled (not to be changed)

SNMP v3 Security Level
and auth/priv-password

auth/priv-pass-
word

The security level can be selected from among
[auth-password] and [auth/priv-password].
An 8-digit-or-more auth-password and priv-
password can both be set.

Print Data Capture

Allow

Restrict (not to be changed)

Network Setting Clear

Enabled

Restrict

Incorrect User Box No.
Entry

Print

Print (Show Error Message can be changed, but
the function cannot be changed to Auto Create
User Box)

c250_security_E.book 9 ページ 2007年4月11日 水曜日 午前11時2分