2.5

Mechanical

2.5.1 Mounting.

Mounting can be done in one of the following methods:

a) Clamping.

Clamping (or hard mounting) is the recommended method and the
only method of mounting in all fixed installations or when operating
from >10V.

Clamping is also the preferred method of mounting in mobile
installations where most electrical interfaces are used.

b) Clip on.

Avalon RF offers a clip on kit. This method is acceptable when
operating from a 9V battery and only one or two interfaces are in
use.

c) Velcro

®

to a flat surface.

The RT423 may be mounted using Velcro

®

if it is required to be

detached frequently. However, in this case it must be operated
from a 9V battery.