SYMPTOM

CHECK POINT

CURE

No sound

Is the amplifier power LED illuminated?

1. Check fuses in amplifier

2. Check turn-on lead

3. Check signal leads

4. Check gain control

5. Check source unit volume

6. Clean contacts on fuse holders

Is the amplifier overload LED illuminated?

Check speaker for short or

amplifier for overheating

Check impedance with Ohm meter

If no reading, replace speaker

Check that the speaker moves freely

If speaker won’t move, replace speaker

Speaker is making a

Check that speaker is secured properly

Tighten mounting screws

rattling noise

and tightened with screws

Check enclosure construction

Check that the enclosure is debris free

Check speaker polarity

Correct polarity

No sound from one coil

Check speaker leads

1. Inspect for short circuits

2. Check for open connections

Reverse left and right speaker leads to

determine if it is occurring before the

speaker

Speaker is distorting at high Check speaker load impedance capabilities

Confirm that the speaker load

volume levels

for the amplifier

impedance recommendations are

followed. Check the wiring

configuration of the speakers.

(To verify proper load impedance, use

an OHM meter to measure the total load

for each channel of the amplifier.

Verify that amplifier and/or crossover settings Select low-pass setting

are correct

Advertising