Asante Technologies 10Base2 User Manual

Page 20

Advertising
background image

Mini MAU

Page

17

Switches for 10Base-F MAU

The default settings are identified below:

❏

Loopback Test Switch
enabled.

(1, switch UP)

❏

HBE Switch disabled.

(1, switch UP)

The default settings are Loopback switch
enabled and HBE Switch disabled.

Loopback Test Switch

When this switch is enabled the AUI trans-
mit pair data is looped back to the AUI
receiver pair. This test can be used for trou-
bleshooting to determine if the returned
signal is the same as the transmitted sig-
nal.

This switch can be disabled.

HBE Switch

The HBE of the Mini 10BaseFL can be dis-
abled by setting the DIP switch to the “UP”
(1) position.