Physical and environmental specifications, Regulatory certifications and approvals – APC IP DSLAM User Manual

Page 7

Advertising
background image

Physical and Environmental Specifications

Description Specification

Dimensions and (H x W x D) 19 inch Rack Mountable.

267 x 440 x 337 mm. (10.5 x 17.3 x 13.3 in)

6 rack-unit (RU) high

Weight

31 kg (68.3 lb) fully configured, 16 kg (35.3 lb) (Backplane only), 1.5 kg (3.3lb) (Interface card).

LED

System status (APC): MASTER/SLAVE and RUN (POWER).

Gigabit port Ethernet: Speed indicator and ACT

NMS port status: LINK/ACT and 10/100 indicator.

ADSL port status: PWR (Power) and ALM (Alarm) and ADSL Link.

SHDSL port status: PWR (Power) and ALM (Alarm) and ADSL Link.

Fan status LED: Green (On) / Orange (Off).

Operating temperature

0 to 50°C (32 to 122°F).

Storage temperature

-30 to 75°C (-22 to 167°F).

Operating relative humidity

5 to 90% (non-condensing).

Operating altitude

Up to 3,000 m (9,842 ft).

Storage altitude

Up to 4,000 m (13,123 ft).

Not intended for use as desktops or in open office environments.

Regulatory Certifications and Approvals

Description Specification

Standards

ADSL line interface:

ANSI T1.413 issue2

ITU-T G.992.1 (G.dmt), G.992.2 (G.lite), G.992.3, G.992.4, G.992.5 Annex A/B/C, G.994.1

Line Code: DMT

Connector Loops: 1 pair (2 wire mode).

Data Rate:

Annex A

Up to 8/24 Mbps (Downstream speed range of ADSL/ADSL2+).

Up to 1 Mbps (Upstream speed range).

Annex B

Up to 8/24 Mbps (Downstream speed range of ADSL/ADSL2+).

Up to 1 Mbps (Upstream speed range).

Annex C (planned for future implementation)

www.corecess.com

Release 1.0 (2004/07/29)

7