AOC P/N : 41A50-144 User Manual

Page 29

Advertising
background image

28

S A M P O C O R P O R A T I O N

TROUBLE SHOOTING OF CHI-MEI INVERTER ( DIVTL0037-D42- -)

9-2 HIGHT VOLTAGE PROTECTION:

FAIL

PASS

9-3 OUTPUT CURRENT ABNORMALITY:

FAIL

PASS

1. SHORT R30 OPEN LOAD

TEST C14 INPUT POINT

VOLTAGE Vh=1600 100V rms

TO CHANGE ON
PT1 OR PT2

FUNCTION TEST OK!

1 CHECK ON C6 FREQUNCY
&CHIP&IC CPIP
2 OSCILLATOR FREQUNCY
RANGE = 100 ~ 250 KHZ

TO CHANGE ON C6
CHIP OR IC CHIP

FUNCTION TEST OK!

Advertising