Adjustment of minimum level

To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the bypass screw position. If you change from natural

gas 20 mbar to liquid gas, fully tighten the adjustment screw in. If you change from

liquid gas to natural gas 20 mbar, undo the by-pass screw approximately 1/4 of a turn

(1/2 of a turn for Triple Crown burner).

1

1

Minimum adjustment screw

5. Make sure the flame does not go out when you quickly turn the knob from the maxi-

mum position to the minimum position.

Electrical connection

• Any electrical work required to install this hob should be carried out by a qualified elec-

trician or competent person, in accordance with the current regulations.

• THIS HOB MUST BE EARTHED.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug after installation.
• Do not pull the mains cable to disconnect the appliance. Always pull the mains plug.
• The appliance must not be connected with an extension cable, an adapter or a multiple

connection (risk of fire). Check that the ground connection is in conformity with the

standard and regulations force.

• The power cable must be placed in such a way that it does not touch any hot part.
• Connect the appliance to the mains with a device that lets to disconnect the appliance

from the mains at all poles with a contact opening width of minimum 3 mm, eg. auto-

matic line protecting cut-out, earth leakage trips or fuse.

• None of a parts of the connection cable can not get a temperature 90°C.

Electrical Requirements

Any permanent electrical installation must comply with the latest I.E.E. Regulations and lo-

cal Electricity Board regulations. For your own safety this should be undertaken by a quali-

fied electrician, e.g. your local Electricity Board, or a contractor who is on the roll of the

National Inspection Council for Electrical Installation Contracting (NICEIC).

The manufacturer declines any liability should these safety measures not be observed.

This hob is designed to be connected to a 230 V 50 Hz AC electrical supply.