7 building in, Kitchen unit with oven – AEG HG755440SM User Manual
Page 15

8.7 Building In
min. 600 mm
min. 55 mm
min. 650 mm
560 mm
480 mm
min. 450 mm
30 mm
B
A
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.8 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy ac-
cess in case a technical assistance inter-
vention is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A)
Removable panel
B)
Space for connections
Kitchen unit with oven
The hob recess dimensions must obey
the indication and the kitchen unit must
be equipped with vents to let a continu-
ous supply of air. The electrical connec-
tion of the hob and the oven must be in-
stalled separately for safety reasons and
to let easy remove oven from the unit.
50 cm
2
360 cm
2
180 cm
2
120 cm
2
ENGLISH
15