1

Green and Yellow:

Earth

3

Brown:

Live

5

Blue:

Neutral

As the colours of the wires in the mains lead of this appliance may not correspond with the

coloured markings identifying the terminals in your plug, proceed as follows:
1.

Connect the wire coloured green and yellow to the terminal marked either with the

letter “E“ or by the earth symbol or coloured green and yellow.

2.

Connect the wire coloured blue to the terminal either marked with the letter “N“ or

coloured black.

3.

Connect the wire coloured brown to the terminal either marked with the “L“ or col-

oured red.

4.

Check that no cut, or stray strands of wire is present and the cord clamp

4

is secure

over the outer sheath.

5.

Make sure the electricity supply voltage is the same as that indicated on the appliance

rating plate.

6.

Switch on the appliance.

The appliance is supplied with a 13 amp plug fitted

2

. In the event of having to change

the fuse in the plug supplied, a 13 amp ASTA approved (BS 1362) fuse must be used.
WARNING!

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that it

is disposed of safely.

Ventilation requirements

The airflow behind the appliance must be suffi-

cient.

NOISES

There are some sounds during normal running (compressor, refrigerant circulation).

50 mm min.

200 cm

2

min.

200 cm