Bbv ?bcb – AMX Modero NXD/NXT-1200VG User Manual

Page 221

Advertising
background image

Programming

207

VG-Series Modero Touch Panels

All custom events have the following 6 fields:

These fields are populated differently for each query command. The text length (String Encode) field is not
used in any command.

Custom Event Fields

Field

Description

Uint Flag

0 means text is a standard string, 1 means Unicode encoded string

slong value1

button state number

slong value2

actual length of string (this is not encoded size)

slong value3

index of first character (usually 1 or same as optional index

string text

the text from the button

text length (string encode)

button text length

Button Query Commands

?BBV

Get the Battery
Base version.

Returned in Custom event.

Text="None" OR "Base/Docking Station Version number"

Note: V1 Panels only

?BCB

Get the current
border color.

Syntax:

"'?BCB-<vt addr range>,<button states range>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).

custom event type 1011:

Flag - zero

Value1 - Button state number

Value2 - Actual length of string (should be 9)

Value3 - Zero

Text - Hex encoded color value (ex: #000000FF)

Text length - Color name length (should be 9)

Example:

SEND COMMAND Panel,"'?BCB-529,1'"

Gets the button 'OFF state' border color. information.

The result sent to the Master would be:

ButtonGet Id = 529 Type = 1011

Flag = 0

VALUE1 = 1

VALUE2 = 9

VALUE3 = 0

TEXT = #222222FF

TEXT LENGTH = 9

Advertising