Programming

216

VG-Series Modero Touch Panels

Button Query Commands (Cont.)

?TXT

Get the current
text information.

Syntax:

"'?TXT-<vt addr range>,<button states range>,<optional index>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).

optional index = This is used if a string was too long to get back in one command.
The reply will start at this index.

custom event type 1001:

Flag - Zero

Value1 - Button state number

Value2 - Actual length of string

Value3 - Index

Text - Text from the button

Text length - Button text length

Example:

SEND COMMAND Panel,"'?TXT-529,1'"

Gets the button 'OFF state' text information.

The result sent to the Master would be:

ButtonGet Id = 529 Type = 1001

Flag = 0

VALUE1 = 1

VALUE2 = 14

VALUE3 = 1

TEXT = This is a test

TEXT LENGTH = 14

?VOL

Get the Master
Volume.

Returned in Custom event.

Value1=master volume value

?WIF

Get the current
wireless

information.

Returned in Custom event.

Text=<WAP MAC address>,<SSID>,<Channel #>,<Signal Level Value>