• A qualified electrician must install the connections in the clamps correctly.
• Use a strain relief clamp on cable.
• Use the correct mains cable of type H05BB-F Tmax 90°C (or higher) for a single phase

or two phase connection.

• Replace the damaged mains cable with a special cable (type H05BB-F Tmax 90°C; or

higher). Speak your local Service Centre.

The appliance must have the electrical installation which lets you disconnect the appli-

ance from the mains at all poles with a contact opening width of minimum 3 mm.

You must have correct devices to isolate: line protecting cut-outs, fuses (screw type

fuses removed from the holder), earth leakage trips and contactors.

Assembly

min. 500 mm

min.

50 mm

min.

50 mm

600 mm

560

+1

mm

R5

490

+1

mm

min.

25 mm

min.

20 mm

min.

28 mm