RECOMMENDED RELATIVE HUMIDITY BY OUTDOOR TEMPERATURE

OUTDOOR TEMP

_

F (_C)

OUTDOOR RELATIVE HUMIDITY

(%)

INDOOR RELATIVE HUMIDITY

(%) W/O HUMIDIFIER*

MAX RECOMMENDED INDOOR

RELATIVE HUMIDITY{

---10 (---23)

30 to 70

1 to 2

20 (Lo)

0 (---18)

30 to 70

2 to 4

25

10 (---12)

30 to 70

3 to 6

30

20 (---7)

30 to 70

4 to 10

35

30 (---1)

30 to 70

6 to 15

40 (Med)

* Indoor relative humidity level when outdoor air is heated to 72_F/22_C.

{

As stipulated by the Air Conditioning Contractors of America.

INDOOR RELATIVE HUMIDITY LIMIT FOR NO WINDOW CONDENSATION

(Indoor Air at 74_F/23_C Dry Bulb)

OUTDOOR TEMPERATURE

_

F (_C)

SINGLE PANE WINDOWS (%)

DOUBLE PANE WINDOWS (%)

40 (4)

39

59

30 (---1)

29

50

20 (---7)

21

43

10 (---12)

15

36

0 (---18)

10

30

---10 (---23)

7

26

---20 (---29)

5

21

---30 (---34)

3

17

MAXIMUM MOISTURE REQUIREMENTS*

VOLUME OF RESIDENCE

CUBIC FEET

(CUBIC METER)

TIGHT HOUSE

AVERAGE HOUSE

POUNDS

(KILOGRAMS) PER

HOUR

GALLONS (LITERS)

PER DAY

POUNDS

(KILOGRAMS) PER

HOUR

GALLONS (LITERS)

PER DAY

8,000 (227)

1.76 (0.8)

5.09 (19)

3.52 (1.6)

10.17 (38)

10,000 (283)

2.21 (1.0)

6.35 (24)

4.41 (2.0)

12.72 (48)

12,000 (340)

2.64 (1.2)

7.63 (29)

5.29 (2.4)

15.26 (58)

14,000 (396)

3.09 (1.4)

8.91 (34)

5.92 (2.7)

17.08 (65)

16,000 (453)

3.53 (1.6)

10.18 (39)

7.06 (3.2)

20.35 (77)

18,000 (510)

3.97 (1.8)

11.45 (43)

7.94 (3.6)

22.89 (87)

20,000 (566)

4.41 (2.0)

12.72 (48)

8.82 (4.0)

25.44 (96)

22,000 (623)

4.85 (2.2)

13.99 (53)

9.71 (4.4)

27.98 (106)

24,000 (680)

5.29 (2.4)

15.27 (58)

10.59 (4.8)

30.52 (116)

26,000 (736)

5.74 (2.6)

16.54 (63)

11.47 (5.2)

33.07 (125)

28,000 (793)

6.18 (2.8)

17.81 (67)

12.35 (5.6)

35.61 (135)

30,000 (850)

6.62 (3.0)

19.08 (72)

13.24 (6.0)

38.16 (144)

* Based on design conditions of outdoor 20_F/---7_C dry bulb, 80% RH; indoor 70_F/21_C dry bulb, 40% RH, and minimum moisture production from residen-

tial operations for an absolute humidity difference of 0.0049 lb/hr.

NOTE:

Tight house is defined as being well insulated, having vapor barriers, tight storm doors and windows with weatherstripping, and having dampered fireplaces.

Average house is defined as being insulated, having vapor barriers, loose storm door and windows and having dampered fireplace.