Data delivery methods, Error conditions – B&B Electronics DCDSS1 User Manual

Page 6

Advertising
background image

Documentation Number DCDSS11702 Manual

Appendix A

3

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Buffer-Based Trigger

The buffer-based trigger automatically dials the modem after the

data buffer is a determined percentage full. The range is from 10%
to 80% in 5% increments. Keeping the buffer trigger below 100%
capacity allows for additional data to be stored while the connection
is being made.

Digital Input Trigger

The digital input trigger dials the modem when an input signal is

detected on the DCDSS1 digital input. It is a +5 volt signal, which
can be set to active high or active low. The signal must stay active
for at least 5 milliseconds to be detected.

Data Delivery Methods

Data and error logs can be emailed using a MIME attachment or

sent using FTP. Additionally, notifications can be configured to allow
email or pager notification that data has been delivered.

Error Conditions

The DCDSS1 has a 2.9 Kbyte error log buffer for storing error

conditions. Each error condition is time stamped.

Error Condition Logged

Cause

BYTE(S) LOST

Data received from the local serial
port during ISP communications or
when in Bypass Mode is not stored

DATA OVERRUN

Onboard UART FIFO overflowed

DATA ERROR

Character received with parity,
framing or break error

NOTIFICATION FAILED

An error occurred in the email
notification process (mail server
connection, command structure,
etc.)

DATA ATTACHMENT FAILED

An error occurred in the email data
process (mail server connection,
command structure, etc.)

ERROR ATTACHMENT
FAILED

An error occurred in the email error
log process (mail server connection,
command structure, etc.)

FTP FAILED

An error occurred in the FTP

process (FTP server connection,