B.

WHEN VENT PIPE EXTENDS TO CHIMNEY TOP

(Refer to Figures 16 and 17)

1.

You will need a pipe length equal to the chimney
height (from hearth) plus 6 inches. If outside
combustion air is to be used, you will need a pipe
length (see “COMBUSTION AIR SUPPLY”) equal to
the chimney height plus 12 inches.


2.

Attach cerablanket wrap (not included) to that end of
vent pipe that will connect to the stove. Use 12-inch
lengths of light gauge metal wire (not included) or
metallic tape (not included). This is to protect interior
components from excess heat.


3.

Set the insert on the hearth and slide it in far enough
to attach the vent pipe (and combustion pipe if used).


4.

Attach flashing (refer to Figure 15), route power cord
out the side nearest a 120V receptacle. Slide in
insert.


5.

Measure and build chimney top. Cut out hole for vent
pipe (and combustion air intake pipe, if used). Install
and seal with a non-hardening mastic to prevent
water leakage. Install the vent cap.


C.

WHEN VENT PIPE EXTENDS THROUGH
CHIMNEY BLANKING PLATE

(Masonry Fireplaces Only)
(Refer to Figures 16 and 17)

1.

You will need a pipe length that extends 12” above
the blanking plate. NOTE: This installation is optional
but not recommended. Outside combustion air
cannot be drawn from the chimney cavity in this
installation.


2.

Attach cerablanket wrap (not included) to that end of
vent pipe that will connect to the stove. Use 12-inch
lengths of light gauge metal wire (not included) or
metallic tape. This is to protect interior components
from excess heat.


3.

Measure and build blanking plate. Cut out hole for
vent pipe (and combustion air intake pipe, if used).
Install and carefully seal blanking plate with non-
hardening mastic. Failure to properly seal may result
in smoke spillage.


4.

Slide vent pipe (and intake pipe if used) up through
the blanking plate hole, leaving enough to pull back
down.


5.

Set the insert on the hearth, adjust the leveling bolts
on the rear sides, slide it in far enough to attach the
vent pipe (and combustion air pipe if used). Be sure
to seal where the pipe passes through the blanking
plate.


6.

Attach flashing (refer to Figure 15), route power cord
out the side nearest a 120V receptacle. Slide in
insert.