Connection, Important – Blanco BC 75 X User Manual

Page 24

Advertising
background image

24

Connection

Carry out the connection to the gas plant

only by means of a rigid metallic pipe

conforming to the regulations in force.
The joint for the entry of gas into the

appliance is threaded GJ 1/2".
Carry out the connection avoiding any type

of stress on the appliance.
Natual gas appliances must be fitted with a

pressure regulator and be installed at the

inlet connection. The gas pressure must

then be set as a part of the commissioning

procedures.
For U-LPG the pressure adjustment is

made via the regulator fitted at the domestic

cylinder.

Important

Upon completion of installation, always

check:

l

that all the joints are completely sealed

by using a soapy solution, never a flame;

l

that the gas pressure has been

regulated to 1.00kPa for Natural Gas

and 2.75kPa for Universal-LPG. The

pressure test point is located on the

regulator for Natural Gas models or at

the top left hand rear of the cooker for

U-LPG models. The pressure should be

measured and adjusted with the Wok

burner on high flame;

l

that the automatic ignition system is

operating satisfactory on all burners,

both individually and in combination;

l

that the burners operate correctly, are

stable, without yellow tipping or

excessive noise on high and low flame.

Then demonstrate to the customer the

appiance operation and leave these

instructions.

Advertising