Potentiometer p1: hold time adjustment, Mounting angles, Passive relay – BEA Superscan User Manual

Page 7

Advertising
background image

75.1035 V1 Feb 2001

Page 7 of 8

PASSIVE RELAY:

The relay is de-energized when the detector is at rest

1. NORMALLY OPEN: Use NO & COM terminals (4 & 6) & CHANGE JP2 from the factory preset position.


Contact closed if detection (green led ON , red led ON)

2. NORMALLY CLOSED: Use the NC & COM terminals (5 & 6) & CHANGE JP2 from the factory preset position.


Contact open if detection (green led ON, red led ON)


Potentiometer P1: Hold Time

Adjustment


The hold time adjustment is altered by the turn of a potentiometer, and refers to the amount of time the output may
be held. A range of 100 mS to 4.5 seconds can be obtained. Clockwise rotation increases hold time.

Mounting

Angles

HINGE SIDE RIGHT HINGE SIDE LEFT

Angles of 0° through 10° shown below

Angles of 15° through 25° shown below










NOTE:

On the approach side, it is recommended to choose the proper mounting angle as well as proper

detection distance

depending on the application, the # of modules used, and the width of the door.

Adjustable angles
from 0º to 25º.